Criteria
The
criteria for receiving the GEEA-label were decided upon by the board of the GEEA
upon a proposal from the working groups. An overview of the criteria is shown
in the table below.
The current complete criteria
are given in the product sheets, which can be downloaded (in pdf-format) by selecting
the link in the product group description headline.
| Product
group |
2007 |
|
TV (digital and analogue broadcasting) |
|
|
|
1 W |
|
|
7 W |
|
|
8 W |
|
|
9 W |
|
VCR Video equipment - with playback function only
(DVD-player, Video Cassette Player) |
|
|
|
1 W (2) |
|
|
11 W |
|
VCR Video recording equipment
(VCR, TV/VCR Combi, DVD-recordable |
|
|
|
2.5 W (2) |
|
- on-mode (applies only to VCR)
|
15 W |
|
Set
Top Box
IRD (digital decoder) including equipment with recording function (PVR) |
|
|
- standby-passive (optional) mode
|
1 W |
|
|
|
|
IRD-Terrestial |
6 W (+ max 9 3 or 14 6) |
|
IRD-Cable |
7 W (+ max 8 3 or 13 6) |
|
IRD-Sattelite |
8 W (+ max 7 3 or 12 6) |
|
IRD-IP (DSL) |
6 W (+ max 9 3 or 14 6) |
|
Set
Top Box
Digital to analogue converter |
|
|
- standby-passive (optional) mode
|
2W 7 |
|
|
|
|
Terrestrial |
7 W (+ 4 8) |
|
Cable |
7 W (+ 4 8) |
|
Satellite |
10 W (+ 2 8) |
|
IP DSL
|
7 W (+ 4 9) (+2 9) |
|
| Product
group |
2007 |
|
| PC (Personal Computers( Desktops, Integrated Computers, Desktop-Derived Servers and Gaming Consoles) |
|
|
|
2 W (+ 0.7 10 W) |
|
- sleep mode (low-power mode):
|
4 W (+ 0.710W) (Preset default< 30 min.) |
|
|
Cat. A: 50 W, Cat. B 65 W, Cat. C 95 W |
|
Additional requirements
|
Compliance of ENERGY STAR Program
Requirements for Computers: Version 4.0,
Eligibility Criteria |
|
| |
|
|
Additional requirement
|
- Corresponds fully to Energy Star criteria
- Cat A, B and C refer to Energy Star
- Additional power allowance in sleep and
standby for WOL: 0.7 W |
|
| Notebooks and tablets |
|
|
|
1 W (+ 0.7 10 W) |
|
|
1.7 W (+ 0.7 10 W) (Preset default< 30 min.) |
|
|
Cat. A. 14 W, Cat. B: 22 W |
|
|
Compliance of ENERGY STAR Program
Requirements for Computers: Version 4.0,
Eligibility Criteria |
|
|
- Corresponds fully to Energy Star criteria
- Cat A, B and C refer to Energy Star
- Additional power allowance in sleep and
standby for WOL: 0.7 W |
|
| Workstations |
|
|
|
0.35 * ((PMax + (#HDDs*5)) W 11 |
|
|
Compliance of ENERGY STAR Program
Requirements for Computers: Version 4.0,
Eligibility Criteria |
|
|
- Corresponds fully to Energy Star criteria
- TEC (Typical Electricity Consumption): 0.1 *
PStandby + 0.2 * PSleep + 0.7 * PIdle
- Pmax is the maximum power drawn by the
system as tested per the test procedure and
#HDD is the number of installed hard drives
in the system. |
|
| |
|
|
| Monitors |
|
|
|
1 W |
|
|
2 W |
|
| |
|
|
|
• Resolution less than 1 megapixel:
23 W
• Resolution larger than or
equal to 1 mega-pixel: 28 W *
resolution in mega-pixels |
|
| Additional requirement |
4 |
|
| Comment |
- Corresponds fully to Energy Star criteria |
|
| Product
group |
2007 |
|
| Broadband Equipment |
|
|
| ADSL/VDSL-modem (powered by USB) * |
|
|
|
0 W |
|
|
1.5 W |
|
| Modems (ADSL, Cable, PLC) * |
|
|
|
0.3 W |
|
|
6 W |
|
| VDSL modem * |
|
|
|
0.3 W |
|
|
8 W |
|
| * Each additional function of the following: WLAN 802.11b/g, WLAN 802.11a, FXO,
FXS/VoIP, hub/switch for several ports, DECT, Bluetooth |
|
|
|
0 |
|
|
+2 W / additional function |
|
| WLAN access point |
|
|
|
0.3 W |
|
|
6 W |
|
| Small printer server |
|
|
|
0.3 W |
|
|
5 W |
|
| VoIP device |
|
|
|
0.3 W |
|
|
5 W |
|
| Small hubs and switches |
|
|
|
0.3 W |
|
|
5 W |
|
| Footnotes: |
| |
|
| 1 |
The
manufacturer of the model to be registered should have signed the
EICTA industry self-commitment, and should no be noted for failing
to meet the self commitment (according to article 5.3 of the self
commitment). |
| 2 |
Factory
default automatically switching to standby-passive after 30 minutes
of inactivity. |
| 3 |
See
Annex B of the Code of Conduct for Digital TV Service Systems.
More information here |
| 4 |
•
Units with external power supply: The power supply should comply with
EU "Code of Conduct on Energy Efficiency of External Power Supplies"
Version 2, phase 2 - see below - full doc. here |
| |
Rated
Output Power (Pno) |
Minimum
Four Point Average or 100 % Load Efficiency in Active Mode
(expressed as a decimal) * |
0 < W <
1 |
< 0.49
* Pno |
1 < W <
49 |
< [0.09
* Ln (Pno)] + 0.49 ** |
49 < W
< 150 |
< 0.84 |
| *. Ln” refers to the natural logarithm. The
algebraic order of operations requires that the natural logarithm
calculation be performed first and then multiplied by 0.09,
with the resulting output added to 0.5. An efficiency of 0.85
in decimal form corresponds to the more familiar value of 85%
when expressed as a percentage |
| ** Power supplies that have a power factor correction
(PFC) to comply with EN61000-3-2 (above 75 W input power) have
a an 0.04 allowance, accordingly the minimum on mode load efficiency
is 0.80 |
|
| |
|
| 5 |
|
|
|
| |
|
|
|
|
|
| 6 |
For high definition, MPEG4 and multi decode platforms |
|
|
| |
|
|
|
| 7 |
manufacturer guarantees that the box switches to standby-passive after a manufacturer factory set default time without any user activity (unless overwritten by the user). |
|
|
| |
|
|
|
| 8 |
the allowance of 4 W is for simple converters for High Definition TV Services (both standard and high definition output) |
|
|
| |
|
|
|
| 9 |
The allowance of 4 W is for simple converters for High Definition TV Services (both standard and high definition output) |
|
|
| |
|
|
|
| 10 |
Additional power allowance in sleep and standby for WOL: 0.7 W. All computers, regardless of distribution channel, shall have the ability to enable and disable WOL for sleep mode. |
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |
|
|
|
| |